Assessment Year | 1988 |
---|---|
Principal Product | PLASTIC COATED WIRES |
NAICS |
n/a
|
SIC | 3357: Drawing and Insulating of Nonferrous Wire |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
n/a
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $132,769 | 1,776,084 |
kWh
|
$0.075 |
Natural Gas | $6,600 | 1,350 |
MMBtu
|
$4.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,638 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,530 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4312: Improve lubrication practices | $1,095 | $800 |
$1,095
14,654
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $905 | $594 |
$905
12,016
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,030 | - |
$4,030
53,634
kWh
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,086 | - |
$1,086
14,361
kWh
|
|
05 | 2.2511: Insulate bare equipment | $319 | $73 |
$319
4,396
kWh
|
|
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,907 | $2,500 |
$1,907
25,498
kWh
|
|
07 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,296 | $420 |
$2,296
30,774
kWh
|
|
TOTAL RECOMMENDED | $11,638 | $4,387 |
$11,638
155,333
kWh
|
||
TOTAL IMPLEMENTED | $6,530 | $873 |
$6,530
87,045
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs