| Assessment Year | 1988 |
|---|---|
| Principal Product | DRUM ACCESSORIES |
| NAICS |
n/a
|
| SIC | 3053: Gaskets, Packing, and Sealing Devices |
| Sales Range | $5 M to 10M |
| # of Employees | 50 |
| Plant Area |
n/a
|
| Annual Production | 37,000,000
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $76,811 | 666,178 |
kWh
|
$0.12 |
| Natural Gas | $22,234 | 4,496 |
MMBtu
|
$4.95 |
| Fuel Oil #2 | $3,045 | 490 |
MMBtu
|
$6.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,565 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,454 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $657 | - |
$657
5,862
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,052 | - |
$2,052
17,878
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $775 | $96 |
$775
6,741
kWh
|
- | |
| 04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,970 | $4,500 |
$(-683.0)
(-5,862)
kWh
|
$4,653
-
MMBtu
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $719 | $3,556 |
$719
6,155
kWh
|
- | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $392 | $500 | - |
$392
-
MMBtu
|
|
| TOTAL RECOMMENDED | $8,565 | $8,652 |
$3,520
30,774
kWh
|
$5,045
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,454 | $4,596 |
$2,801
24,619
kWh
|
$4,653
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs