| Assessment Year | 1988 |
|---|---|
| Principal Product | PRINTED LABELS & SEALS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 316 |
| Plant Area |
n/a
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $54,216 | 747,948 |
kWh
|
$0.072 |
| Natural Gas | $33,620 | 6,006 |
MMBtu
|
$5.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,702 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,200 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,617 | $682 |
$4,617
59,203
kWh
|
- | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $409 | $202 |
$409
5,569
kWh
|
- | - | |
| 03 | 2.6232: Install set-back timers | $8,562 | - |
$8,562
117,233
kWh
|
- | - | |
| 04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $3,810 | $3,104 |
$3,872
53,048
kWh
|
- | $(-62.0) | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,692 | $1,800 |
$1,692
21,688
kWh
|
- | - | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,612 | $500 | - |
$1,612
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $20,702 | $6,288 |
$19,152
256,741
kWh
|
$1,612
-
MMBtu
|
$(-62.0) | ||
| TOTAL IMPLEMENTED | $15,200 | $1,384 |
$13,588
182,005
kWh
|
$1,612
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs