Assessment Year | 1988 |
---|---|
Principal Product | PLASTIC CARRYING CASES |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
n/a
|
Annual Production | 275,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $61,055 | 492,087 |
kWh
|
$0.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,794 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,679 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $496 | $132 |
$496
4,103
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $227 | $72 |
$227
1,758
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,848 | - |
$2,848
22,860
kWh
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,108 | - |
$1,108
8,792
kWh
|
|
05 | 2.4322: Use or replace with energy efficient substitutes | $11,115 | $11,004 |
$11,115
89,683
kWh
|
|
TOTAL RECOMMENDED | $15,794 | $11,208 |
$15,794
127,196
kWh
|
||
TOTAL IMPLEMENTED | $4,679 | $204 |
$4,679
37,513
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs