ITAC Assessment: RU0021
ITAC logo
ITAC Assessment: RU0021
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1988
Principal Product LAND MOBILE COMMERCIAL PRODUCTS
NAICS
n/a
SIC 3663: Radio and Television Broadcasting and Communications Equipment
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area
n/a
Annual Production 3,000,000
pieces
Production Hrs. Annual 2,423
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $141,036 1,557,737
kWh
Natural Gas $47,618 9,033
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $9,070 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $6,481

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,128 $370 $1,128
12,896
kWh
-
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $302 - $302
3,224
kWh
-
03 2.4312: Improve lubrication practices $109 - $109
1,172
kWh
-
04 2.6211: Conserve energy by efficient use of vending machines $956 $800 $956
10,551
kWh
-
05 2.7221: Lower temperature during the winter season and vice-versa $2,480 $2,151 - $2,480
-
MMBtu
06 2.7447: Install vinyl strip / high speed / air curtain doors $4,095 $400 $2,325
25,791
kWh
$1,770
-
MMBtu
TOTAL RECOMMENDED $9,070 $3,721 $4,820
53,634
kWh
$4,250
-
MMBtu
TOTAL IMPLEMENTED $6,481 $1,570 $4,711
52,462
kWh
$1,770
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs