Assessment Year | 1988 |
---|---|
Principal Product | FOOD SERVICE HARDWARE |
NAICS |
n/a
|
SIC | 3429: Hardware, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 280 |
Plant Area |
n/a
|
Annual Production | 25,000,000
pieces
|
Production Hrs. Annual | 5,148
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $219,491 | 3,274,033 |
kWh
|
$0.067 |
Natural Gas | $157,239 | 29,972 |
MMBtu
|
$5.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,238 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,391 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,019 | $209 |
$4,019
59,789
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,164 | - |
$4,164
62,134
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,736 | $302 |
$1,736
25,791
kWh
|
- | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,847 | $5,040 |
$(-446.0)
(-6,741)
kWh
|
$4,293
-
MMBtu
|
|
05 | 2.4312: Improve lubrication practices | $764 | $800 |
$764
11,430
kWh
|
- | |
06 | 2.2514: Cover open tanks | $2,983 | $200 |
$2,983
44,549
kWh
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,725 | - |
$6,725
100,528
kWh
|
- | |
TOTAL RECOMMENDED | $24,238 | $6,551 |
$19,945
297,480
kWh
|
$4,293
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,391 | $1,511 |
$20,391
304,221
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs