Assessment Year 1985
Principal Product FABRICATED STEEL PRODUCT
NAICS
n/a
SIC 3498: Fabricated Pipe and Pipe Fittings
Sales Range $10
M
to 50
M
# of Employees 252
Plant Area
n/a
Annual Production 5,280
ton
Production Hrs. Annual 3,000
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $328,332 4,283,998
kWh
Natural Gas $143,927 25,237
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $71,762 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $36,014 $129 $36,014
470,106
kWh
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $15,526 $27 - $15,526
-
MMBtu
03 2.7231: Use radiant heater for spot heating $1,012 $4,800 - $1,012
-
MMBtu
04 2.4133: Use most efficient type of electric motors $616 $1,181 $616
7,913
kWh
-
05 2.4221: Install compressor air intakes in coolest locations $3,166 $79 $3,166
41,325
kWh
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $15,428 - $15,428
201,348
kWh
-
TOTAL RECOMMENDED $71,762 $6,216 $55,224
720,692
kWh
$16,538
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs