Assessment Year | 1990 |
---|---|
Principal Product | DIMENSIONAL LUMBER |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $50 M to 100M |
# of Employees | 70 |
Plant Area |
n/a
|
Annual Production | 220,000
thousand feet
|
Production Hrs. Annual | 4,008
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $661,731 | 14,054,514 |
kWh
|
$0.047 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,737 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $43,128 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $16,426 | - |
$16,426
414,127
kWh
|
- | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $457 | - |
$457
12,309
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $8,401 | - |
$8,401
178,781
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $14,404 | $5,000 |
$14,404
306,565
kWh
|
- | |
05 | 2.6232: Install set-back timers | $12,298 | $1,600 |
$9,467
256,155
kWh
|
$2,831 | |
06 | 2.4133: Use most efficient type of electric motors | $9,674 | $938 |
$9,674
205,451
kWh
|
- | |
07 | 2.3212: Optimize plant power factor | $4,077 | - |
$4,077
-
kWh
|
- | |
TOTAL RECOMMENDED | $65,737 | $7,538 |
$62,906
1,373,388
kWh
|
$2,831 | ||
TOTAL IMPLEMENTED | $43,128 | $6,600 |
$40,297
976,847
kWh
|
$2,831 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs