Assessment Year 2016
Principal Product Processed beef, poultry, and pork
NAICS 311611: Animal (except Poultry) Slaughtering
SIC 2011: Meat Packing Plants
Sales Range greater than $500
M
# of Employees 1,000
Plant Area 328,000
ft2
Annual Production 250,000,000
units
Production Hrs. Annual 7,488
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,553,645 39,837,047
kWh
Electricity Demand $1,316,560 75,275
kW-mo/yr
Natural Gas $515,881 88,218
MMBtu
TOTAL YEARLY COSTS $3,386,086
RECOMMENDED SAVINGS* $303,038 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,579

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $48,548 $62,561 $29,607
759,142
kWh
$18,942
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,244 $12,740 $4,244
108,808
kWh
- - -
03 2.2414: Use waste heat from hot flue gases to preheat $26,114 $42,500 - - - $26,114
-
MMBtu
04 2.1233: Analyze flue gas for proper air/fuel ratio $8,904 $3,000 - - - $8,904
-
MMBtu
05 2.7224: Reduce space conditioning during non-working hours $5,675 $2,816 $1,171
30,015
kWh
- - $4,505
-
MMBtu
06 2.7241: Install outside air damper / economizer on hvac unit $1,980 $7,000 $1,980
50,777
kWh
- - -
07 2.4221: Install compressor air intakes in coolest locations $17,684 $1,972 $10,286
263,734
kWh
$7,398
-
kW-mo/yr
- -
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $14,014 $4,000 $14,014
359,322
kWh
- - -
09 2.6231: Utilize controls to operate equipment only when needed $159,843 $40,000 $159,843
4,098,545
kWh
- - -
10 2.3132: Recharge batteries on during off-peak demand periods $13,152 - - - $13,152 -
11 2.6212: Turn off equipment during breaks, reduce operating time $2,880 - $2,880
73,854
kWh
- - -
TOTAL RECOMMENDED $303,038 $176,589 $224,024
5,744,197
kWh
$26,340
-
kW-mo/yr
$13,152 $39,523
-
MMBtu
TOTAL IMPLEMENTED $14,579 $5,816 $1,171
30,015
kWh
- - $13,409
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs