Assessment Year | 2010 |
---|---|
Principal Product | abrasives |
NAICS | 327910: Abrasive Product Manufacturing |
SIC | 3291: Abrasive Products |
Sales Range | $10 M to 50M |
# of Employees | 22 |
Plant Area |
28,000
ft2
|
Annual Production | 60,000,000
pieces
|
Production Hrs. Annual | 2,295
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $54,495 | 600,660 |
kWh
|
$0.091 |
Electricity Demand | $15,834 | 2,059 |
kW-mo/yr
|
$7.69 |
Electricity Fees | $11,069 | - |
|
- |
LPG | $15,931 | 515 |
MMBtu
|
$30.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,582 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,066 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $11,345 | $1,020 |
$7,842
87,130
kWh
|
$3,503
-
kW-mo/yr
|
|
02 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $4,171 | $2,804 |
$3,725
41,404
kWh
|
$446
-
kW-mo/yr
|
|
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,721 | $2,507 |
$1,881
20,898
kWh
|
$840
-
kW-mo/yr
|
|
04 | 2.7245: Use direct air supply to exhaust hoods | $2,587 | $700 |
$1,787
19,853
kWh
|
$800
-
kW-mo/yr
|
|
05 | 2.7425: Clean or color roof to reduce solar load | $1,758 | $4,871 |
$1,215
13,500
kWh
|
$543
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $22,582 | $11,902 |
$16,450
182,785
kWh
|
$6,132
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $14,066 | $3,527 |
$9,723
108,028
kWh
|
$4,343
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs