Assessment Year | 2016 |
---|---|
Principal Product | PE Pipes |
NAICS | 326122: Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
98,000
ft2
|
Annual Production | 4,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $303,877 | 6,898,732 |
kWh
|
$0.044 | |
Electricity Demand | $130,091 | 21,816 |
kW-mo/yr
|
$5.96 | |
Natural Gas | $13,233 | 4,134 |
MMBtu
|
$3.20 | |
Waste Disposal Costs | |||||
Water Usage | $12,433 | 3,506 |
Tgal
|
$3.55 | |
Water Disposal | $17,611 | 1,754 |
Tgal
|
$10.04 | |
TOTAL YEARLY COSTS | $477,245 | ||||
RECOMMENDED SAVINGS* | $39,773 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2622: Replace existing chiller with high efficiency model | $11,871 | $92,000 |
$11,871
269,808
kWh
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $985 | $3,780 |
$985
22,386
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,495 | $9,720 |
$2,023
45,984
kWh
|
$472
-
kW-mo/yr
|
- | - | |
04 | 2.2511: Insulate bare equipment | $11,683 | $10,036 |
$11,683
265,521
kWh
|
- | - | - | |
05 | 2.7231: Use radiant heater for spot heating | $3,754 | $19,570 | - | - | - |
$3,754
-
MMBtu
|
|
06 | 2.6232: Install set-back timers | $483 | $410 |
$393
8,935
kWh
|
- | - |
$90
-
MMBtu
|
|
07 | 2.3212: Optimize plant power factor | $4,680 | $27,500 | - | - | $4,680 | - | |
08 | 2.4221: Install compressor air intakes in coolest locations | $368 | $822 |
$368
8,379
kWh
|
- | - | - | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,092 | $2,000 |
$3,092
70,295
kWh
|
- | - | - | |
10 | 2.6218: Turn off equipment when not in use | $362 | $540 |
$362
8,236
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $39,773 | $166,378 |
$30,777
699,544
kWh
|
$472
-
kW-mo/yr
|
$4,680 |
$3,844
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs