ITAC Assessment: OK0909
ITAC logo
ITAC Assessment: OK0909
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product Processed meat
NAICS 311612: Meat Processed from Carcasses
SIC 2013: Sausages and Other Prepared Meat Products
Sales Range $10
M
to 50
M
# of Employees 469
Plant Area 189,000
ft2
Annual Production 140,000,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,410,007 25,855,500
kWh
Electricity Demand $580,883 46,805
kW-mo/yr
Natural Gas $940,001 175,545
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $408,102 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $82,568

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7261: Install timers and/or thermostats $3,077 - $1,828
33,230
kWh
- - $1,249
-
MMBtu
02 2.7241: Install outside air damper / economizer on hvac unit $2,799 $7,680 $2,799
50,894
kWh
- - -
03 2.7232: Replace existing hvac unit with high efficiency model $4,249 $8,691 $4,249
77,259
kWh
- - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $797 $3,904 $797
14,498
kWh
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $11,514 $34,454 $8,461
153,834
kWh
$3,053
-
kW-mo/yr
- -
06 2.1233: Analyze flue gas for proper air/fuel ratio $10,211 $2,000 - - - $10,211
-
MMBtu
07 2.2136: Install / repair insulation on steam lines $300 $377 - - - $300
-
MMBtu
08 2.1233: Analyze flue gas for proper air/fuel ratio $34,856 $41,000 - - - $34,856
-
MMBtu
09 2.1121: Use insulation in furnaces to facilitate heating / cooling $1,404 $824 - - - $1,404
-
MMBtu
10 2.4221: Install compressor air intakes in coolest locations $4,060 $1,875 $4,060
73,822
kWh
- - -
11 2.2437: Recover waste heat from equipment $25,364 $2,846 $11,669
212,160
kWh
- - $13,695
-
MMBtu
12 2.2437: Recover waste heat from equipment $43,900 $87,882 $(-1,076.3)
(-19,569)
kWh
$(-333.2)
-
kW-mo/yr
- $45,309
-
MMBtu
13 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat $265,571 $1,832,665 - - $173,047 $92,524
-
MMBtu
TOTAL RECOMMENDED $408,102 $2,024,198 $32,787
596,128
kWh
$2,720
-
kW-mo/yr
$173,047 $199,548
-
MMBtu
TOTAL IMPLEMENTED $82,568 $60,129 $21,153
384,604
kWh
- - $61,415
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs