Assessment Year | 2015 |
---|---|
Principal Product | Oil field equipment |
NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 96 |
Plant Area |
92,700
ft2
|
Annual Production | 50
pieces
|
Production Hrs. Annual | 3,250
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $72,156 | 907,882 |
kWh
|
$0.079 |
Natural Gas | $34,023 | 5,011 |
MMBtu
|
$6.79 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,758 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,534 | $2,400 |
$3,534
44,732
kWh
|
- | |
02 | 2.4322: Use or replace with energy efficient substitutes | $98 | $77 |
$98
1,236
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $146 | $463 |
$146
1,848
kWh
|
- | |
04 | 2.2437: Recover waste heat from equipment | $468 | $1,220 | - |
$468
-
MMBtu
|
|
05 | 2.4226: Use / purchase optimum sized compressor | $1,180 | $2,817 |
$1,180
14,944
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $920 | $2,441 |
$920
11,641
kWh
|
- | |
07 | 2.7134: Use photocell controls | $2,888 | $3,680 |
$2,888
36,551
kWh
|
- | |
08 | 2.7122: Disconnect ballasts | $627 | $144 |
$627
7,933
kWh
|
- | |
09 | 2.6218: Turn off equipment when not in use | $296 | $476 |
$296
3,744
kWh
|
- | |
10 | 2.6232: Install set-back timers | $3,337 | $192 |
$2,896
37,122
kWh
|
$441
-
MMBtu
|
|
11 | 2.7232: Replace existing hvac unit with high efficiency model | $8,784 | $8,940 |
$10,957
138,691
kWh
|
$(-2,172.8)
-
MMBtu
|
|
12 | 4.623: Employ modular jigs to reduce process set-up time | $1,749 | $1,248 |
$1,749
22,136
kWh
|
- | |
13 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,731 | $8,268 |
$2,731
34,567
kWh
|
- | |
TOTAL RECOMMENDED | $26,758 | $32,366 |
$28,021
355,145
kWh
|
$(-1,263.5)
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs