Assessment Year | 2013 |
---|---|
Principal Product | Pizza crust & pastries |
NAICS | 311813: Frozen Cakes, Pies, and Other Pastries Manufacturing |
SIC | 2038: Frozen Specialties, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
80,000
ft2
|
Annual Production | 15,000,000
lb
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $160,875 | 2,827,596 |
kWh
|
$0.057 |
Electricity Demand | $49,318 | 8,225 |
kW-mo/yr
|
$6.00 |
Natural Gas | $36,363 | 6,780 |
MMBtu
|
$5.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $71,914 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,534 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7241: Install outside air damper / economizer on hvac unit | $18,260 | $28,000 |
$18,260
320,355
kWh
|
- | - | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $14,259 | $28,400 |
$11,793
206,902
kWh
|
$2,466
-
kW-mo/yr
|
- | |
03 | 2.2628: Utilize a less expensive cooling method | $19,312 | $184,080 |
$16,013
280,938
kWh
|
$3,299
-
kW-mo/yr
|
- | |
04 | 2.7211: Clean and maintain refrigerant condensers and towers | $4,776 | $1,440 |
$3,960
69,458
kWh
|
$816
-
kW-mo/yr
|
- | |
05 | 2.6232: Install set-back timers | $449 | $318 |
$165
2,899
kWh
|
- |
$284
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $865 | $3,992 |
$865
15,170
kWh
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,853 | $22,216 |
$2,205
38,687
kWh
|
$648
-
kW-mo/yr
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $299 | $463 |
$299
5,242
kWh
|
- | - | |
09 | 2.2437: Recover waste heat from equipment | $5,915 | $2,598 | - | - |
$5,915
-
MMBtu
|
|
10 | 2.2121: Increase amount of condensate returned | $1,019 | $700 | - | - |
$1,019
-
MMBtu
|
|
11 | 2.2511: Insulate bare equipment | $232 | $280 | - | - |
$232
-
MMBtu
|
|
12 | 2.1231: Establish burner maintenance schedule for boilers | $2,408 | $2,686 |
$2,408
42,257
kWh
|
- | - | |
13 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $189 | $2,098 |
$115
2,009
kWh
|
- |
$75
-
MMBtu
|
|
14 | 2.7423: Reduce heat gain by window tinting | $1,077 | $16,000 |
$573
10,052
kWh
|
- |
$504
-
MMBtu
|
|
TOTAL RECOMMENDED | $71,914 | $293,271 |
$56,656
993,968
kWh
|
$7,229
-
kW-mo/yr
|
$8,029
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,534 | $18,038 |
$4,698
82,409
kWh
|
$816
-
kW-mo/yr
|
$1,020
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs