Assessment Year | 2013 |
---|---|
Principal Product | Heat Exchangers |
NAICS | 332410: Power Boiler and Heat Exchanger Manufacturing |
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
164,283
ft2
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $174,605 | 2,956,990 |
kWh
|
$0.059 |
Electricity Demand | $118,298 | 17,603 |
kW-mo/yr
|
$6.72 |
Natural Gas | $56,205 | 9,957 |
MMBtu
|
$5.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $74,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,167 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $3,227 | $1,723 |
$3,227
54,698
kWh
|
- | - | - | |
02 | 2.7241: Install outside air damper / economizer on hvac unit | $3,823 | $5,100 |
$3,823
68,400
kWh
|
- | - | - | |
03 | 2.7231: Use radiant heater for spot heating | $3,126 | $26,250 | - | - | - |
$3,126
-
MMBtu
|
|
04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,366 | $14,850 |
$(-1,157.0)
(-19,605)
kWh
|
- | - |
$4,523
-
MMBtu
|
|
05 | 2.2121: Increase amount of condensate returned | $3,223 | $3,250 | - | - | - |
$3,223
-
MMBtu
|
|
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,722 | $1,750 |
$2,722
46,129
kWh
|
- | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $986 | $513 |
$986
16,709
kWh
|
- | - | - | |
08 | 2.2437: Recover waste heat from equipment | $3,206 | $847 | - | - | - |
$3,206
-
MMBtu
|
|
09 | 2.4322: Use or replace with energy efficient substitutes | $2,499 | $3,850 |
$2,499
42,355
kWh
|
- | - | - | |
10 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $14,580 | $12,694 | - | - | $14,580 | - | |
11 | 2.4322: Use or replace with energy efficient substitutes | $32,972 | $69,860 |
$28,522
483,428
kWh
|
$4,450
-
kW-mo/yr
|
- | - | |
12 | 2.7135: Install occupancy sensors | $445 | $3,675 |
$445
7,535
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $74,175 | $144,362 |
$41,067
699,649
kWh
|
$4,450
-
kW-mo/yr
|
$14,580 |
$14,078
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,167 | $5,425 |
$3,167
53,664
kWh
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs