Assessment Year | 2006 |
---|---|
Principal Product | Salts for livestock and water treatment |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 25 |
Plant Area |
52,325
ft2
|
Annual Production | 120,000
ton
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $211,251 | 3,420,600 |
kWh
|
$0.062 |
Natural Gas | $316,916 | 29,980 |
MMBtu
|
$10.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $163,688 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,766 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,431 | $2,462 |
$4,035
72,307
kWh
|
$396
-
kW-mo/yr
|
- | - | - | |
02 | 2.7261: Install timers and/or thermostats | $1,646 | $75 | - | - | - |
$1,646
-
MMBtu
|
- | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $12,463 | $40,452 |
$10,476
187,745
kWh
|
- | - |
$1,987
-
MMBtu
|
- | |
04 | 2.5124: Use gravity feeds wherever possible | $10,056 | $1,636 |
$10,342
185,340
kWh
|
$1,014
-
kW-mo/yr
|
- | - | $(-1,300.0) | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,960 | $8,407 |
$1,725
30,910
kWh
|
$235
-
kW-mo/yr
|
- | - | - | |
06 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $117,767 | $838,833 | - | - | $117,767 | - | - | |
07 | 2.2511: Insulate bare equipment | $14,689 | $7,635 | - | - | - |
$14,689
-
MMBtu
|
- | |
08 | 2.7135: Install occupancy sensors | $676 | $535 |
$676
12,106
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $163,688 | $900,035 |
$27,254
488,408
kWh
|
$1,645
-
kW-mo/yr
|
$117,767 |
$18,322
-
MMBtu
|
$(-1,300.0) | ||
TOTAL IMPLEMENTED | $20,766 | $10,172 |
$4,035
72,307
kWh
|
$396
-
kW-mo/yr
|
- |
$16,335
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs