Assessment Year | 1996 |
---|---|
Principal Product | Pipe fittings and flanges |
NAICS |
n/a
|
SIC | 3498: Fabricated Pipe and Pipe Fittings |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
870,000
ft2
|
Annual Production | 9,600
ton
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $178,078 | 3,804,807 |
kWh
|
$0.047 |
Electricity Demand | $768 | 9,290 |
kW-mo/yr
|
$0.083 |
Natural Gas | $377,203 | 157,737 |
MMBtu
|
$2.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,650 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,636 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1231: Establish burner maintenance schedule for boilers | $1,243 | - | - |
$1,243
-
MMBtu
|
- | - | |
02 | 2.1122: Re-size charging openings or add a movable door on equipment | $14,966 | $18,000 | - |
$11,066
-
MMBtu
|
- | $3,900 | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $2,414 | $9,615 | - |
$2,414
-
MMBtu
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $2,419 | $855 | - |
$2,419
-
MMBtu
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $470 | $460 |
$23
879
kWh
|
$447
-
MMBtu
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $538 | $248 | - |
$538
-
MMBtu
|
- | - | |
07 | 3.8143: Recycle cleaning solvent and reuse | $600 | $6,901 | - | - |
$600
-
gal
|
- | |
TOTAL RECOMMENDED | $22,650 | $36,079 |
$23
879
kWh
|
$18,127
-
MMBtu
|
$600
-
gal
|
$3,900 | ||
TOTAL IMPLEMENTED | $19,636 | $19,563 |
$23
879
kWh
|
$15,713
-
MMBtu
|
- | $3,900 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs