Assessment Year | 1995 |
---|---|
Principal Product | Magazines, Commercial printing |
NAICS |
n/a
|
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
330,000
ft2
|
Annual Production | 457,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,094,579 | 25,478,312 |
kWh
|
$0.043 |
Natural Gas | $419,662 | 114,998 |
MMBtu
|
$3.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $128,363 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $112,074 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2612: Use cooling tower water instead of refrigeration | $63,653 | $25,000 |
$63,653
1,473,916
kWh
|
- | - | - | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $28,374 | $48,000 |
$38,799
733,587
kWh
|
$(-10,425.0)
-
MMBtu
|
- | - | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $5,482 | $2,520 |
$5,482
126,905
kWh
|
- | - | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $3,490 | $2,500 |
$3,490
80,891
kWh
|
- | - | - | |
05 | 2.7144: Install spectral reflectors / delamp | $2,792 | $160 |
$2,792
53,634
kWh
|
- | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $2,382 | $1,650 |
$2,382
55,100
kWh
|
- | - | - | |
07 | 2.7132: Install timers on light switches in little used areas | $2,143 | $1,000 |
$2,143
49,531
kWh
|
- | - | - | |
08 | 2.3132: Recharge batteries on during off-peak demand periods | $1,578 | $1,000 |
$1,578
-
kWh
|
- | - | - | |
09 | 3.8136: Switch to a solvent that can be cleaned and re-used | $8,089 | $4,295 | - | - | - |
$8,089
-
gal
|
|
10 | 3.4131: Minimize contamination of water before treatment | $6,080 | $500 | - | - |
$6,080
-
Tgal
|
- | |
11 | 3.6192: Use a less expensive method of waste removal | $4,300 | - | - | - |
$4,300
-
Tgal
|
- | |
TOTAL RECOMMENDED | $128,363 | $86,625 |
$120,319
2,573,564
kWh
|
$(-10,425.0)
-
MMBtu
|
$10,380
-
Tgal
|
$8,089
-
gal
|
||
TOTAL IMPLEMENTED | $112,074 | $78,795 |
$104,030
2,207,503
kWh
|
$(-10,425.0)
-
MMBtu
|
$10,380
-
Tgal
|
$8,089
-
gal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs