Assessment Year 1995
Principal Product Magazines, Commercial printing
NAICS
n/a
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 330,000
ft2
Annual Production 457,000,000
pieces
Production Hrs. Annual 8,400
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,094,579 25,478,312
kWh
Natural Gas $419,662 114,998
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $128,363 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $112,074

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings Other Liquid (haz) Savings
01 2.2612: Use cooling tower water instead of refrigeration $63,653 $25,000 $63,653
1,473,916
kWh
- - -
02 2.1311: Replace electrically-operated equipment with fossil fuel equipment $28,374 $48,000 $38,799
733,587
kWh
$(-10,425.0)
-
MMBtu
- -
03 2.6231: Utilize controls to operate equipment only when needed $5,482 $2,520 $5,482
126,905
kWh
- - -
04 2.7111: Reduce illumination to minimum necessary levels $3,490 $2,500 $3,490
80,891
kWh
- - -
05 2.7144: Install spectral reflectors / delamp $2,792 $160 $2,792
53,634
kWh
- - -
06 2.4221: Install compressor air intakes in coolest locations $2,382 $1,650 $2,382
55,100
kWh
- - -
07 2.7132: Install timers on light switches in little used areas $2,143 $1,000 $2,143
49,531
kWh
- - -
08 2.3132: Recharge batteries on during off-peak demand periods $1,578 $1,000 $1,578
-
kWh
- - -
09 3.8136: Switch to a solvent that can be cleaned and re-used $8,089 $4,295 - - - $8,089
-
gal
10 3.4131: Minimize contamination of water before treatment $6,080 $500 - - $6,080
-
Tgal
-
11 3.6192: Use a less expensive method of waste removal $4,300 - - - $4,300
-
Tgal
-
TOTAL RECOMMENDED $128,363 $86,625 $120,319
2,573,564
kWh
$(-10,425.0)
-
MMBtu
$10,380
-
Tgal
$8,089
-
gal
TOTAL IMPLEMENTED $112,074 $78,795 $104,030
2,207,503
kWh
$(-10,425.0)
-
MMBtu
$10,380
-
Tgal
$8,089
-
gal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings Other Liquid (haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs