Assessment Year | 2014 |
---|---|
Principal Product | Pre-fabricated mobile modules |
NAICS | 332311: Prefabricated Metal Building and Component Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
50,000
ft2
|
Annual Production | 2,340
pieces
|
Production Hrs. Annual | 2,225
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $44,843 | 460,726 |
kWh
|
$0.097 |
Electricity Demand | $13,848 | 1,967 |
kW-mo/yr
|
$7.04 |
Electricity Fees | $1,881 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,983 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,983 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $10,980 | $15,030 | - | - | - | $10,980 | |
02 | 2.7134: Use photocell controls | $4,405 | $6,900 |
$4,405
51,830
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,860 | $4,450 |
$2,110
24,830
kWh
|
$750
-
kW-mo/yr
|
- | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $1,308 | $3,000 | - | - | $1,308 | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,230 | $1,035 |
$875
10,300
kWh
|
$355
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,330 | $11 |
$960
11,320
kWh
|
$370
-
kW-mo/yr
|
- | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $450 | $430 |
$410
4,880
kWh
|
$40
-
kW-mo/yr
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $420 | $500 |
$300
3,500
kWh
|
$120
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $22,983 | $31,356 |
$9,060
106,660
kWh
|
$1,635
-
kW-mo/yr
|
$1,308 | $10,980 | ||
TOTAL IMPLEMENTED | $22,983 | $31,356 |
$9,060
106,660
kWh
|
$1,635
-
kW-mo/yr
|
$1,308 | $10,980 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs