Assessment Year | 1994 |
---|---|
Principal Product | Sheet metal products for environmental systems |
NAICS |
n/a
|
SIC | 3353: Aluminum Sheet, Plate, and Foil |
Sales Range | $10 M to 50M |
# of Employees | 280 |
Plant Area |
250,000
ft2
|
Annual Production | 879,560
lb
|
Production Hrs. Annual | 4,110
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $213,598 | 1,930,246 |
kWh
|
$0.11 |
Natural Gas | $19,368 | 7,867 |
MMBtu
|
$2.46 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,188 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,582 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,582 | - |
$4,582
58,030
kWh
|
- | - | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $4,255 | $5,951 |
$5,012
58,324
kWh
|
$(-757.0)
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,211 | $10,107 |
$4,211
37,515
kWh
|
- | - | |
04 | 2.8121: Apply for tax-free status for energy purchases | $2,892 | - | - | - | $2,892 | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,471 | - |
$1,471
17,878
kWh
|
- | - | |
06 | 2.7224: Reduce space conditioning during non-working hours | $1,254 | $600 |
$1,254
121,043
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $849 | $276 |
$849
10,551
kWh
|
- | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $519 | - |
$519
6,448
kWh
|
- | - | |
09 | 2.6232: Install set-back timers | $155 | $162 |
$155
2,052
kWh
|
- | - | |
TOTAL RECOMMENDED | $20,188 | $17,096 |
$18,053
311,841
kWh
|
$(-757.0)
-
MMBtu
|
$2,892 | ||
TOTAL IMPLEMENTED | $4,582 | - |
$4,582
58,030
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs