Assessment Year | 1992 |
---|---|
Principal Product | SUCKER RODS |
NAICS |
n/a
|
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
n/a
|
Annual Production | 290,000
pieces
|
Production Hrs. Annual | 2,750
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $149,070 | 2,154,455 |
kWh
|
$0.069 |
Natural Gas | $99,477 | 36,882 |
MMBtu
|
$2.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,858 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,651 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $17,190 | $35,000 | - |
$17,190
-
MMBtu
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,318 | - |
$8,538
142,145
kWh
|
- | $(-220.0) | |
03 | 2.7123: Keep lamps and reflectors clean | $2,549 | $11,123 |
$2,549
39,566
kWh
|
- | - | |
04 | 2.7123: Keep lamps and reflectors clean | $327 | $1,881 |
$327
4,982
kWh
|
- | - | |
05 | 2.6232: Install set-back timers | $207 | $372 |
$207
3,517
kWh
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $758 | $816 | - |
$758
-
MMBtu
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $509 | $4,350 |
$509
7,913
kWh
|
- | - | |
TOTAL RECOMMENDED | $29,858 | $53,542 |
$12,130
198,123
kWh
|
$17,948
-
MMBtu
|
$(-220.0) | ||
TOTAL IMPLEMENTED | $29,651 | $53,170 |
$11,923
194,606
kWh
|
$17,948
-
MMBtu
|
$(-220.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs