Assessment Year | 1989 |
---|---|
Principal Product | POLYURETHANE FOAM |
NAICS |
n/a
|
SIC | 3432: Plumbing Fixture Fittings and Trim |
Sales Range | $10 M to 50M |
# of Employees | 121 |
Plant Area |
n/a
|
Annual Production | 120,000
thousand feet
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,530 | 2,113,130 |
kWh
|
$0.047 |
Natural Gas | $22,015 | 6,969 |
MMBtu
|
$3.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,881 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,881 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $566 | $224 |
$566
13,189
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,276 | $4,000 |
$2,276
63,599
kWh
|
- | |
03 | 2.7261: Install timers and/or thermostats | $190 | $215 | - |
$190
-
MMBtu
|
|
04 | 2.4133: Use most efficient type of electric motors | $115 | $571 |
$115
4,689
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $471 | - |
$471
19,050
kWh
|
- | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,263 | $4,800 | - |
$2,263
-
MMBtu
|
|
TOTAL RECOMMENDED | $5,881 | $9,810 |
$3,428
100,527
kWh
|
$2,453
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,881 | $9,810 |
$3,428
100,527
kWh
|
$2,453
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs