ITAC Assessment: OK0220
ITAC logo
ITAC Assessment: OK0220
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1987
Principal Product SOFT DRINKS
NAICS
n/a
SIC 2086: Bottled and Canned Soft Drinks and Carbonated Waters
Sales Range $5
M
to 10
M
# of Employees 52
Plant Area
n/a
Annual Production 1,000,000
pieces
Production Hrs. Annual 3,380
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $43,415 655,920
kWh
Natural Gas $21,584 4,728
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $3,003 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,685

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $134 $70 $142
2,345
kWh
$(-8.0)
-
MMBtu
-
02 2.7111: Reduce illumination to minimum necessary levels $746 $100 $800
12,896
kWh
$(-81.0)
-
MMBtu
$27
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $298 - $298
4,103
kWh
- -
04 2.1233: Analyze flue gas for proper air/fuel ratio $281 $800 - $281
-
MMBtu
-
05 2.2136: Install / repair insulation on steam lines $61 $193 - $61
-
MMBtu
-
06 2.7261: Install timers and/or thermostats $204 $550 - $204
-
MMBtu
-
07 2.7231: Use radiant heater for spot heating $976 $2,400 - $976
-
MMBtu
-
08 2.6232: Install set-back timers $178 - $164
2,638
kWh
- $14
09 2.4133: Use most efficient type of electric motors $54 $62 $54
879
kWh
- -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $71 $83 $74
1,465
kWh
$(-3.0)
-
MMBtu
-
TOTAL RECOMMENDED $3,003 $4,258 $1,532
24,326
kWh
$1,430
-
MMBtu
$41
TOTAL IMPLEMENTED $1,685 $865 $1,532
24,326
kWh
$112
-
MMBtu
$41
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs