| Assessment Year | 1996 |
|---|---|
| Principal Product | Medical Test Kits |
| NAICS |
n/a
|
| SIC | 3845: Electromedical and Electrotherapeutic Apparatus |
| Sales Range | $5 M to 10M |
| # of Employees | 81 |
| Plant Area |
48,000
ft2
|
| Annual Production | 73,000
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,795 | 1,060,668 |
kWh
|
$0.062 |
| Electricity Demand | $35,460 | 2,837 |
kW-mo/yr
|
$12.50 |
| Natural Gas | $12,688 | 1,811 |
MMBtu
|
$7.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,210 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,040 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,142 | $31,230 |
$6,077
97,890
kWh
|
$7,065
-
kW-mo/yr
|
- | |
| 02 | 2.7135: Install occupancy sensors | $2,898 | $5,940 |
$1,340
21,688
kWh
|
$1,558
-
kW-mo/yr
|
- | |
| 03 | 2.7224: Reduce space conditioning during non-working hours | $1,819 | - |
$1,819
29,308
kWh
|
- | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $698 | $1,346 |
$430
7,034
kWh
|
$268
-
kW-mo/yr
|
- | |
| 05 | 3.3125: Use distillation, evaporation to remove contaminants | $653 | $2,800 | - | - |
$653
-
gal
|
|
| TOTAL RECOMMENDED | $19,210 | $41,316 |
$9,666
155,920
kWh
|
$8,891
-
kW-mo/yr
|
$653
-
gal
|
||
| TOTAL IMPLEMENTED | $16,040 | $37,170 |
$7,417
119,578
kWh
|
$8,623
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs