Assessment Year 1984
Principal Product OIL FIELD EQUIPMENT
NAICS
n/a
SIC 3533: Oil and Gas Field Machinery and Equipment
Sales Range $5
M
to 10
M
# of Employees 60
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 2,000
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $20,597 345,545
kWh
Natural Gas $6,727 1,327
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $1,873 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,411

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2437: Recover waste heat from equipment $680 $369 - $680
-
MMBtu
02 2.7447: Install vinyl strip / high speed / air curtain doors $462 $516 - $462
-
MMBtu
03 2.7261: Install timers and/or thermostats $65 $165 - $65
-
MMBtu
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $50 $97 $50
1,758
kWh
-
05 2.7111: Reduce illumination to minimum necessary levels $346 - $346
5,862
kWh
-
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $43 $105 $43
1,465
kWh
-
07 2.7111: Reduce illumination to minimum necessary levels $105 $90 $105
3,517
kWh
-
08 2.7142: Utilize higher efficiency lamps and/or ballasts $122 $104 $122
2,052
kWh
-
TOTAL RECOMMENDED $1,873 $1,446 $666
14,654
kWh
$1,207
-
MMBtu
TOTAL IMPLEMENTED $1,411 $930 $666
14,654
kWh
$745
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs