Assessment Year | 1983 |
---|---|
Principal Product | OIL & GAS DRILLING PDTS. |
NAICS |
n/a
|
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 2,000
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $201,355 | 4,859,906 |
kWh
|
$0.041 |
Natural Gas | $37,284 | 10,647 |
MMBtu
|
$3.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,534 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $1,033 | - |
$1,033
19,930
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,482 | $1,779 |
$1,482
28,722
kWh
|
- | |
03 | 2.7261: Install timers and/or thermostats | $13,322 | $100 | - |
$13,322
-
MMBtu
|
|
04 | 2.3191: Use demand controller or load shedder | $2,697 | - | - |
$2,697
-
MMBtu
|
|
TOTAL RECOMMENDED | $18,534 | $1,879 |
$2,515
48,652
kWh
|
$16,019
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs