Assessment Year | 2007 |
---|---|
Principal Product | PVC Packaging Film |
NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $100 M to 500M |
# of Employees | 232 |
Plant Area |
330,000
ft2
|
Annual Production | 96,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,994,869 | 34,545,703 |
kWh
|
$0.058 |
Natural Gas | $284,551 | 13,562 |
MMBtu
|
$20.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $66,764 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,531 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,131 | $1,172 |
$3,131
56,724
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $47,685 | $32,900 |
$(-1,245.0)
(-22,561)
kWh
|
$48,930
-
MMBtu
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $14,548 | $8,000 |
$14,548
263,549
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,400 | $750 |
$1,400
25,303
kWh
|
- | |
TOTAL RECOMMENDED | $66,764 | $42,822 |
$17,834
323,015
kWh
|
$48,930
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,531 | $1,922 |
$4,531
82,027
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs