ITAC Assessment: OK0032
ITAC logo
ITAC Assessment: OK0032
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1982
Principal Product AGITATORS-MIXERS
NAICS
n/a
SIC 3569: General Industrial Machinery and Equipment, Not Elsewhere
Sales Range $5
M
to 10
M
# of Employees 50
Plant Area
n/a
Annual Production 720
pieces
Production Hrs. Annual 2,080
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $20,657 450,176
kWh
Natural Gas $4,904 1,904
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $2,538 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,217 $120 $2,217
70,633
kWh
-
02 2.6232: Install set-back timers $46 - $46
1,465
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $107 $170 $107
3,517
kWh
-
04 2.7261: Install timers and/or thermostats $168 $400 - $168
-
MMBtu
TOTAL RECOMMENDED $2,538 $690 $2,370
75,615
kWh
$168
-
MMBtu
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs