| Assessment Year | 1982 |
|---|---|
| Principal Product | PLASTIC PIPE |
| NAICS |
n/a
|
| SIC | 3084: Plastics Pipe |
| Sales Range | $10 M to 50M |
| # of Employees | 400 |
| Plant Area |
n/a
|
| Annual Production | 80,000,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,241,577 | 21,470,106 |
kWh
|
$0.058 |
| Natural Gas | $35,421 | 13,953 |
MMBtu
|
$2.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,680 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $173 | $293 |
$173
4,689
kWh
|
- | |
| 02 | 2.3212: Optimize plant power factor | $14,183 | $18,620 |
$14,183
-
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $3,084 | $3,247 |
$3,084
123,388
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $3,202 | $290 |
$3,202
147,421
kWh
|
- | |
| 05 | 2.7261: Install timers and/or thermostats | $223 | $500 | - |
$223
-
MMBtu
|
|
| 06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $4,815 | $90,000 |
$5,897
95,545
kWh
|
$(-1,082.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $25,680 | $112,950 |
$26,539
371,043
kWh
|
$(-859.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs