Assessment Year | 1998 |
---|---|
Principal Product | Carbon Fiber Sailboat Mast & Spar |
NAICS |
n/a
|
SIC | 3732: Boat Building and Repairing |
Sales Range | $5 M to 10M |
# of Employees | 52 |
Plant Area |
38,000
ft2
|
Annual Production | 120
pieces
|
Production Hrs. Annual | 4,433
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,145 | 723,623 |
kWh
|
$0.042 |
Electricity Demand | $25,357 | 2,673 |
kW-mo/yr
|
$9.49 |
Electricity Fees | $1,026 | - |
|
- |
Natural Gas | $15,319 | 2,467 |
MMBtu
|
$6.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,194 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,620 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $284 | $70 |
$143
3,517
kWh
|
$141
-
kW-mo/yr
|
- | |
02 | 2.4224: Upgrade controls on compressors | $1,034 | $500 |
$1,034
24,912
kWh
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $6,540 | $7,980 | - | - |
$6,540
-
MMBtu
|
|
04 | 2.7243: Improve air circulation with destratification fans / other methods | $821 | $1,300 |
$(-83.0)
(-2,052)
kWh
|
$(-51.0)
-
kW-mo/yr
|
$955
-
MMBtu
|
|
05 | 2.7261: Install timers and/or thermostats | $4,515 | $1,400 |
$1,007
12,896
kWh
|
- |
$3,508
-
MMBtu
|
|
TOTAL RECOMMENDED | $13,194 | $11,250 |
$2,101
39,273
kWh
|
$90
-
kW-mo/yr
|
$11,003
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,620 | $2,770 |
$1,067
14,361
kWh
|
$90
-
kW-mo/yr
|
$4,463
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs