Assessment Year | 1996 |
---|---|
Principal Product | Mushroom Spawn |
NAICS |
n/a
|
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 25 |
Plant Area |
42,000
ft2
|
Annual Production | 300,000
units
|
Production Hrs. Annual | 4,368
hrs
|
Location (State) | Nevada |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $47,364 | 1,094,373 |
kWh
|
$0.043 |
Electricity Demand | $27,563 | 2,972 |
kW-mo/yr
|
$9.27 |
Electricity Fees | $600 | - |
|
- |
Natural Gas | $26,997 | 5,180 |
MMBtu
|
$5.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,497 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,087 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,596 | $100 |
$1,596
36,928
kWh
|
- | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $248 | $310 |
$248
5,862
kWh
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $336 | - |
$336
7,913
kWh
|
- | - | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $416 | - |
$262
6,155
kWh
|
$154
-
kW-mo/yr
|
- | - | |
05 | 2.7135: Install occupancy sensors | $315 | $246 |
$234
5,569
kWh
|
$81
-
kW-mo/yr
|
- | - | |
06 | 2.7134: Use photocell controls | $474 | $42 |
$218
4,982
kWh
|
$256
-
kW-mo/yr
|
- | - | |
07 | 2.7261: Install timers and/or thermostats | $468 | $1,520 | - | - |
$468
-
MMBtu
|
- | |
08 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $2,775 | $850 | - | - |
$2,775
-
MMBtu
|
- | |
09 | 3.5317: Sell / offer by-product as animal feed | $14,869 | $700 | - | - | - |
$14,869
-
lb
|
|
TOTAL RECOMMENDED | $21,497 | $3,768 |
$2,894
67,409
kWh
|
$491
-
kW-mo/yr
|
$3,243
-
MMBtu
|
$14,869
-
lb
|
||
TOTAL IMPLEMENTED | $5,087 | $2,780 |
$1,844
42,790
kWh
|
- |
$3,243
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs