| Assessment Year | 1995 |
|---|---|
| Principal Product | Fabricated Metal Products |
| NAICS |
n/a
|
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 208 |
| Plant Area |
160,000
ft2
|
| Annual Production | 26,000,000
lb
|
| Production Hrs. Annual | 6,794
hrs
|
| Location (State) | Nevada |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $127,280 | 1,748,828 |
kWh
|
$0.073 |
| Natural Gas | $56,975 | 11,410 |
MMBtu
|
$4.99 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $26,367 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,309 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,290 | $543 |
$1,290
17,878
kWh
|
- | |
| 02 | 2.3212: Optimize plant power factor | $665 | $2,154 |
$665
-
kWh
|
- | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $15,874 | $13,000 | - |
$15,874
-
MMBtu
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,519 | $240 |
$1,519
20,809
kWh
|
- | |
| 05 | 2.7442: Keep doors and windows shut when not on use | $6,854 | $4,119 | - |
$6,854
-
MMBtu
|
|
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $165 | - |
$165
2,345
kWh
|
- | |
| TOTAL RECOMMENDED | $26,367 | $20,056 |
$3,639
41,032
kWh
|
$22,728
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $8,309 | $4,662 |
$1,455
20,223
kWh
|
$6,854
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs