| Assessment Year | 2026 |
|---|---|
| Principal Product | Specialty Automotive Tools |
| NAICS | 332216: Saw Blade and Handtool Manufacturing |
| SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
300,000
ft2
|
| Annual Production | 7,600,000
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $184,522 | 2,601,491 |
kWh
|
$0.071 | |
| Electricity Demand | $17,152 | 2,768 |
kW-mo/yr
|
$6.20 | |
| Electricity Fees | $9,633 | - |
|
- | |
| Natural Gas | $37,608 | 4,978 |
MMBtu
|
$7.55 | |
| Other Gas | $6,568 | 1 |
MMBtu
|
$6,568.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $14,987 | 1,161 |
Tgal
|
$12.91 | |
| Water Disposal | $14,714 | 1,161 |
Tgal
|
$12.67 | |
| Other Liquid (non-haz) | $1,978 | 1 |
gal
|
$1,978.00 | |
| TOTAL YEARLY COSTS | $287,162 | ||||
| RECOMMENDED SAVINGS* | $38,438 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.4111: Use closed cycle process to minimize waste water production | $14,253 | $29,883 |
$(-1,177.0)
(-16,579)
kWh
|
$(-1,007.0)
-
kW-mo/yr
|
- |
$8,296
-
Tgal
|
$8,141
-
Tgal
|
- | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,443 | $5,000 |
$11,443
161,172
kWh
|
- | - | - | - | $(-900.0) | $(-100.0) | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,157 | $29,281 |
$8,292
116,796
kWh
|
- | - | - | - | $1,865 | - | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $1,664 | $3,007 |
$1,664
23,444
kWh
|
- | - | - | - | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,352 | $2,746 |
$1,352
19,042
kWh
|
- | - | - | - | - | - | |
| 06 | 2.7261: Install timers and/or thermostats | $347 | $644 | - | - |
$347
-
MMBtu
|
- | - | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $151 | $250 |
$60
841
kWh
|
- | - | - | - | $91 | - | |
| 08 | 2.7444: Close holes and openings in building such as broken windows | $71 | $65 | - | - |
$71
-
MMBtu
|
- | - | - | - | |
| TOTAL RECOMMENDED | $38,438 | $70,876 |
$21,634
304,716
kWh
|
$(-1,007.0)
-
kW-mo/yr
|
$418
-
MMBtu
|
$8,296
-
Tgal
|
$8,141
-
Tgal
|
$1,056 | $(-100.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs