Assessment Year | 2019 |
---|---|
Principal Product | Mining Equipment |
NAICS | 333131: Mining Machinery and Equipment Manufacturing |
SIC | 3532: Mining Machinery and Equipment, Except Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
210,000
ft2
|
Annual Production | 408
units
|
Production Hrs. Annual | 4,966
hrs
|
Location (State) | South Dakota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $73,187 | 1,876,600 |
kWh
|
$0.039 | |
Electricity Demand | $105,725 | 8,084 |
kW-mo/yr
|
$13.08 | |
Electricity Fees | $960 | - |
|
- | |
Natural Gas | $59,012 | 11,689 |
MMBtu
|
$5.05 | |
Waste Disposal Costs | |||||
Water Usage | $463 | 153 |
Tgal
|
$3.02 | |
Water Disposal | $1,287 | 153 |
Tgal
|
$8.41 | |
TOTAL YEARLY COSTS | $240,633 | ||||
RECOMMENDED SAVINGS* | $65,802 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $48,867 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $36,555 | $34,820 |
$20,545
525,249
kWh
|
$16,010
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7243: Improve air circulation with destratification fans / other methods | $16,935 | $18,980 |
$(-597.0)
(-15,308)
kWh
|
$(-468.0)
-
kW-mo/yr
|
- | - | - | $18,000 | |
03 | 2.4226: Use / purchase optimum sized compressor | $8,170 | $35,828 |
$3,572
91,581
kWh
|
$4,598
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.8114: Change rate schedules or other changes in utility service | $1,867 | - | - | - | - | - | $1,867 | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,450 | $1,600 |
$1,670
42,850
kWh
|
- | $(-120.0) | $(-100.0) | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $825 | $2,025 |
$825
21,159
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $65,802 | $93,253 |
$26,015
665,531
kWh
|
$20,140
-
kW-mo/yr
|
$(-120.0) | $(-100.0) | $1,867 | $18,000 | ||
TOTAL IMPLEMENTED | $48,867 | $74,273 |
$26,612
680,839
kWh
|
$20,608
-
kW-mo/yr
|
$(-120.0) | $(-100.0) | $1,867 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs