Assessment Year | 2000 |
---|---|
Principal Product | printed material |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $100 M to 500M |
# of Employees | 215 |
Plant Area |
44,000
ft2
|
Annual Production | 10,000
lb
|
Production Hrs. Annual | 8,112
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $92,456 | 1,310,082 |
kWh
|
$0.071 |
Electricity Demand | $29,033 | 3,619 |
kW-mo/yr
|
$8.02 |
Electricity Fees | $111 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,407 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,785 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,141 | $13,908 |
$2,221
35,756
kWh
|
$920
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,259 | $880 |
$276
3,810
kWh
|
$38
-
kW-mo/yr
|
$467 | $478 | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $747 | $20 |
$627
10,258
kWh
|
$120
-
kW-mo/yr
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $546 | $500 |
$458
7,327
kWh
|
$88
-
kW-mo/yr
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $176 | $80 |
$176
2,931
kWh
|
- | - | - | - | |
06 | 2.4151: Develop a repair/replace policy | $3,350 | $8,587 |
$2,812
45,428
kWh
|
$538
-
kW-mo/yr
|
- | - | - | |
07 | 3.5217: Reuse / recycle/ sell paper products | $4,188 | $200 | - | - | - | - | $4,188 | |
TOTAL RECOMMENDED | $13,407 | $24,175 |
$6,570
105,510
kWh
|
$1,704
-
kW-mo/yr
|
$467 | $478 | $4,188 | ||
TOTAL IMPLEMENTED | $4,785 | $9,547 |
$3,264
52,169
kWh
|
$576
-
kW-mo/yr
|
$467 | $478 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs