| Assessment Year | 2002 |
|---|---|
| Principal Product | Year Books |
| NAICS |
n/a
|
| SIC | 2732: Book Printing |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
75,000
ft2
|
| Annual Production | 400,000
pieces
|
| Production Hrs. Annual | 4,940
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,949 | 1,585,800 |
kWh
|
$0.042 |
| Electricity Demand | $42,822 | 402 |
kW-mo/yr
|
$106.52 |
| Electricity Fees | $7,357 | - |
|
- |
| Natural Gas | $19,476 | 3,439 |
MMBtu
|
$5.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,503 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,843 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,845 | $110 |
$1,249
27,219
kWh
|
$596
-
kW-mo/yr
|
- | |
| 02 | 2.4314: Use synthetic lubricant | $833 | $300 |
$623
13,582
kWh
|
$210
-
kW-mo/yr
|
- | |
| 03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $16,303 | $14,000 |
$12,843
279,970
kWh
|
$3,460
-
kW-mo/yr
|
- | |
| 04 | 3.4151: Minimize water usage | $4,827 | $18,490 | - | - |
$4,827
-
Tgal
|
|
| 05 | 3.4151: Minimize water usage | $695 | - | - | - |
$695
-
Tgal
|
|
| TOTAL RECOMMENDED | $24,503 | $32,900 |
$14,715
320,771
kWh
|
$4,266
-
kW-mo/yr
|
$5,522
-
Tgal
|
||
| TOTAL IMPLEMENTED | $18,843 | $14,110 |
$14,092
307,189
kWh
|
$4,056
-
kW-mo/yr
|
$695
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs