Assessment Year | 2000 |
---|---|
Principal Product | Food wrappers |
NAICS |
n/a
|
SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
80,000
ft2
|
Annual Production | 25,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,527 | 1,889,508 |
kWh
|
$0.045 |
Electricity Demand | $19,022 | 4,039 |
kW-mo/yr
|
$4.71 |
Natural Gas | $39,728 | 10,703 |
MMBtu
|
$3.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $151,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,920 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.5217: Reuse / recycle/ sell paper products | $63,400 | $8,200 | - | - | - | - |
$40,000
-
lb
|
- | - | - | $23,400 | |
02 | 3.5131: Recycle white water | $36,888 | - | - | - | - |
$488
-
gal
|
- | - | $36,400 | - | - | |
03 | 2.7314: Reduce ventilation air | $15,439 | $1,000 |
$1,849
41,325
kWh
|
$372
-
kW-mo/yr
|
$13,218
-
MMBtu
|
- | - | - | - | - | - | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $6,036 | $20 | - | - |
$6,036
-
MMBtu
|
- | - | - | - | - | - | |
05 | 2.7243: Improve air circulation with destratification fans / other methods | $2,124 | $4,800 |
$(-126.0)
(-2,931)
kWh
|
$(-25.0)
-
kW-mo/yr
|
$2,275
-
MMBtu
|
- | - | - | - | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,226 | $24,870 |
$13,452
301,583
kWh
|
$2,774
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $6,647 | - |
$5,528
123,681
kWh
|
$1,119
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $2,572 | $200 |
$2,139
47,773
kWh
|
$433
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
09 | 2.7135: Install occupancy sensors | $721 | $800 |
$600
13,482
kWh
|
$121
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
10 | 2.7134: Use photocell controls | $190 | $400 |
$123
2,638
kWh
|
$67
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
11 | 2.2711: Utilize outside air instead of conditioned air for drying | $120 | $375 |
$100
2,345
kWh
|
$20
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
12 | 2.4221: Install compressor air intakes in coolest locations | $268 | $200 |
$223
4,982
kWh
|
$45
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
13 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $340 | $400 |
$205
4,689
kWh
|
$204
-
kW-mo/yr
|
$(-69.0)
-
MMBtu
|
- | - | - | - | - | - | |
14 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $204 | $275 |
$56
1,172
kWh
|
$8
-
kW-mo/yr
|
- | - | - | $96 | - | $44 | - | |
TOTAL RECOMMENDED | $151,175 | $41,540 |
$24,149
540,739
kWh
|
$5,138
-
kW-mo/yr
|
$21,460
-
MMBtu
|
$488
-
gal
|
$40,000
-
lb
|
$96 | $36,400 | $44 | $23,400 | ||
TOTAL IMPLEMENTED | $46,920 | $26,090 |
$22,968
514,362
kWh
|
$4,698
-
kW-mo/yr
|
$19,254
-
MMBtu
|
- | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs