ITAC Assessment: ND0307
ITAC logo
ITAC Assessment: ND0307
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1998
Principal Product Flat-rolled Steel
NAICS
n/a
SIC 3444: Sheet Metal Work
Sales Range $5
M
to 10
M
# of Employees 60
Plant Area 96,400
ft2
Annual Production 230,000
ton
Production Hrs. Annual 8,640
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $145,577 2,666,764
kWh
Electricity Demand $57,791 5,450
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,102 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $327 $400 n/a $146
2,638
kWh
$39
-
kW-mo/yr
- $142 -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $792 $2,640 n/a $560
21,981
kWh
$232
-
kW-mo/yr
- - -
03 2.4226: Use / purchase optimum sized compressor $2,847 $8,000 n/a $2,242
41,032
kWh
$605
-
kW-mo/yr
- - -
04 2.4221: Install compressor air intakes in coolest locations $3,424 $900 n/a $3,424
62,720
kWh
- - - -
05 2.8121: Apply for tax-free status for energy purchases $7,112 $250 n/a - - $7,112 - -
06 2.4151: Develop a repair/replace policy $46,021 $15,765 n/a $5,308
61,841
kWh
$4,187
-
kW-mo/yr
- - $36,526
07 2.3212: Optimize plant power factor $4,579 $6,640 n/a - $4,579
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $65,102 $34,595 $11,680
190,212
kWh
$9,642
-
kW-mo/yr
$7,112 $142 $36,526
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs