Assessment Year 1998
Principal Product Plastic fabric
NAICS
n/a
SIC 2241: Narrow Fabric and Other Smallware Mills: Cotton, Wool, Silk, and Manmade Fiber
Sales Range $10
M
to 50
M
# of Employees 66
Plant Area 200,000
ft2
Annual Production 5,500,000
lb
Production Hrs. Annual 8,400
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $34,189 1,179,953
kWh
Electricity Demand $26,238 2,507
kW-mo/yr
Natural Gas $6,555 1,157
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,977 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,897

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
01 2.7111: Reduce illumination to minimum necessary levels $5,258 $300 $5,258
79,426
kWh
- - - - -
02 4.711: Initiate a total quality management program $2,729 - - - $2,729 - - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,570 $40 $1,570
30,188
kWh
- - - - -
04 4.811: Demolish old building to reduce tax and insurance bills $905 $250 - - $905 - - -
05 2.4221: Install compressor air intakes in coolest locations $802 $500 $802
12,016
kWh
- - - - -
06 3.5316: Contract a wood pallet recycling company $540 - - - - - $540
-
lb
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $486 $750 $153
5,275
kWh
$295
-
kW-mo/yr
- - - $38
08 2.4311: Recover mechanical energy $466 $600 - - - $466
-
MMBtu
- -
09 2.7122: Disconnect ballasts $423 $160 $423
8,206
kWh
- - - - -
10 2.7142: Utilize higher efficiency lamps and/or ballasts $350 $550 $173
3,224
kWh
- - - - $177
11 2.7135: Install occupancy sensors $295 $800 $295
9,672
kWh
- - - - -
12 3.7198: Reduce / eliminate use of disposable product $107 $450 - - - - $107
-
lb
-
13 2.7447: Install vinyl strip / high speed / air curtain doors $46 $78 $7
293
kWh
- - $39
-
MMBtu
- -
TOTAL RECOMMENDED $13,977 $4,478 $8,681
148,300
kWh
$295
-
kW-mo/yr
$3,634 $505
-
MMBtu
$647
-
lb
$215
TOTAL IMPLEMENTED $11,897 $2,268 $7,790
127,198
kWh
$295
-
kW-mo/yr
$2,729 $505
-
MMBtu
$540
-
lb
$38
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs