Assessment Year | 1997 |
---|---|
Principal Product | Printed Materials |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 86 |
Plant Area |
44,000
ft2
|
Annual Production | 1,000,000,000
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $42,869 | 1,147,421 |
kWh
|
$0.037 |
Electricity Demand | $9,938 | 3,808 |
kW-mo/yr
|
$2.61 |
Natural Gas | $14,586 | 2,947 |
MMBtu
|
$4.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,292 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,153 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,825 | $3,400 |
$1,577
42,204
kWh
|
$1,248
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,398 | $1,350 |
$1,391
37,222
kWh
|
$1,007
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,285 | $348 |
$1,391
37,222
kWh
|
$894
-
kW-mo/yr
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $443 | $40 |
$241
6,448
kWh
|
$202
-
kW-mo/yr
|
- | - | - | |
05 | 3.1191: Change procedures / equipment / operating conditions | $306 | $360 | - | - | - | - | $306 | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $287 | - | - | - |
$287
-
MMBtu
|
- | - | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $257 | $96 |
$44
1,172
kWh
|
$39
-
kW-mo/yr
|
$174
-
MMBtu
|
- | - | |
08 | 4.611: Begin a practice of predictive / preventative maintenance | $170 | - | - | - | - | $170 | - | |
09 | 3.8221: Use alternatives for acids / alkaline (water, steam, abrasive) | $128 | $100 | - | - | - | - | $128 | |
10 | 2.4221: Install compressor air intakes in coolest locations | $99 | $100 |
$99
2,638
kWh
|
- | - | - | - | |
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $89 | $20 |
$44
1,172
kWh
|
$45
-
kW-mo/yr
|
- | - | - | |
12 | 2.6218: Turn off equipment when not in use | $5 | $73 | - |
$5
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $9,292 | $5,887 |
$4,787
128,078
kWh
|
$3,440
-
kW-mo/yr
|
$461
-
MMBtu
|
$170 | $434 | ||
TOTAL IMPLEMENTED | $8,153 | $5,218 |
$4,502
120,458
kWh
|
$3,194
-
kW-mo/yr
|
$287
-
MMBtu
|
$170 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs