Assessment Year | 1997 |
---|---|
Principal Product | Automotive parts |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 174 |
Plant Area |
170,000
ft2
|
Annual Production | 5,200,000
pieces
|
Production Hrs. Annual | 6,384
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $271,760 | 11,288,101 |
kWh
|
$0.024 |
Electricity Demand | $190,837 | 22,987 |
kW-mo/yr
|
$8.30 |
Natural Gas | $49,210 | 13,672 |
MMBtu
|
$3.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,774 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $2,118 | $600 | n/a |
$2,118
87,925
kWh
|
- | - | - |
02 | 2.2437: Recover waste heat from equipment | $16,897 | $10,000 | n/a | - | - |
$16,897
-
MMBtu
|
- |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $670 | $1,053 | n/a |
$406
16,120
kWh
|
$264
-
kW-mo/yr
|
- | - |
04 | 2.6218: Turn off equipment when not in use | $5 | $17 | n/a |
$5
293
kWh
|
- | - | - |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $158 | $450 | n/a |
$158
1,758
kWh
|
- | - | - |
06 | 4.811: Demolish old building to reduce tax and insurance bills | $9,928 | $150 | n/a | - | - | - | $9,928 |
07 | 2.7444: Close holes and openings in building such as broken windows | $1,531 | $240 | n/a |
$673
27,843
kWh
|
- |
$858
-
MMBtu
|
- |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,377 | $340 | n/a |
$1,377
57,151
kWh
|
- | - | - |
09 | 2.4133: Use most efficient type of electric motors | $3,090 | $2,400 | n/a |
$2,208
52,755
kWh
|
$882
-
kW-mo/yr
|
- | - |
TOTAL RECOMMENDED | $35,774 | $15,250 |
$6,945
243,845
kWh
|
$1,146
-
kW-mo/yr
|
$17,755
-
MMBtu
|
$9,928 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs