| Assessment Year | 1997 |
|---|---|
| Principal Product | Automotive parts |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 174 |
| Plant Area |
170,000
ft2
|
| Annual Production | 5,200,000
pieces
|
| Production Hrs. Annual | 6,384
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $271,760 | 11,288,101 |
kWh
|
$0.024 |
| Electricity Demand | $190,837 | 22,987 |
kW-mo/yr
|
$8.30 |
| Natural Gas | $49,210 | 13,672 |
MMBtu
|
$3.60 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,774 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $2,118 | $600 | n/a |
$2,118
87,925
kWh
|
- | - | - |
| 02 | 2.2437: Recover waste heat from equipment | $16,897 | $10,000 | n/a | - | - |
$16,897
-
MMBtu
|
- |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $670 | $1,053 | n/a |
$406
16,120
kWh
|
$264
-
kW-mo/yr
|
- | - |
| 04 | 2.6218: Turn off equipment when not in use | $5 | $17 | n/a |
$5
293
kWh
|
- | - | - |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $158 | $450 | n/a |
$158
1,758
kWh
|
- | - | - |
| 06 | 4.811: Demolish old building to reduce tax and insurance bills | $9,928 | $150 | n/a | - | - | - | $9,928 |
| 07 | 2.7444: Close holes and openings in building such as broken windows | $1,531 | $240 | n/a |
$673
27,843
kWh
|
- |
$858
-
MMBtu
|
- |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,377 | $340 | n/a |
$1,377
57,151
kWh
|
- | - | - |
| 09 | 2.4133: Use most efficient type of electric motors | $3,090 | $2,400 | n/a |
$2,208
52,755
kWh
|
$882
-
kW-mo/yr
|
- | - |
| TOTAL RECOMMENDED | $35,774 | $15,250 |
$6,945
243,845
kWh
|
$1,146
-
kW-mo/yr
|
$17,755
-
MMBtu
|
$9,928 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs