| Assessment Year | 1997 |
|---|---|
| Principal Product | Machined metal products |
| NAICS |
n/a
|
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
37,000
ft2
|
| Annual Production | 500,000
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $23,016 | 385,404 |
kWh
|
$0.060 |
| Natural Gas | $8,694 | 2,035 |
MMBtu
|
$4.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,358 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7444: Close holes and openings in building such as broken windows | $227 | $245 | - |
$227
-
MMBtu
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $360 | $900 |
$360
6,448
kWh
|
- | - | - | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $61 | $170 | - |
$61
-
MMBtu
|
- | - | |
| 04 | 2.4131: Size electric motors for peak operating efficiency | $250 | $700 |
$250
5,862
kWh
|
- | - | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $149 | $400 |
$149
2,638
kWh
|
- | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $380 | $200 |
$380
6,155
kWh
|
- | - | - | |
| 07 | 2.6218: Turn off equipment when not in use | $131 | - |
$131
3,224
kWh
|
- | - | - | |
| 08 | 2.8112: Combine utility meters | $720 | $2,880 | - | - | $720 | - | |
| 09 | 4.811: Demolish old building to reduce tax and insurance bills | $134 | $160 | - | - | $134 | - | |
| 10 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $765 | $982 | - |
$765
-
MMBtu
|
- | - | |
| 11 | 3.5316: Contract a wood pallet recycling company | $72 | - | - | - | - | $72 | |
| 12 | 3.8132: Use less toxic and volatile solvent substitutes | $109 | - | - | - | - | $109 | |
| TOTAL RECOMMENDED | $3,358 | $6,637 |
$1,270
24,327
kWh
|
$1,053
-
MMBtu
|
$854 | $181 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs