| Assessment Year | 1996 |
|---|---|
| Principal Product | Sewage Vacuum Pumps |
| NAICS |
n/a
|
| SIC | 3492: Fluid Power Valves and Hose Fittings |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
18,300
ft2
|
| Annual Production | 6,000
pieces
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $12,933 | 242,966 |
kWh
|
$0.053 |
| Electricity Fees | $848 | - |
|
- |
| Natural Gas | $9,490 | 1,857 |
MMBtu
|
$5.11 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,391 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $892 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $700 | $250 | - | $700 | - | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $110 | $280 |
$110
2,052
kWh
|
- | - | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $132 | - |
$132
2,345
kWh
|
- | - | - | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $348 | $2,770 |
$348
6,448
kWh
|
- | - | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $45 | $150 |
$45
879
kWh
|
- | - | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $401 | $723 |
$401
7,327
kWh
|
- | - | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $93 | $620 |
$93
1,758
kWh
|
- | - | - | - | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $432 | $197 | - | - |
$432
-
MMBtu
|
- | - | |
| 09 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $494 | $262 | - | - |
$494
-
MMBtu
|
- | - | |
| 10 | 2.7111: Reduce illumination to minimum necessary levels | $547 | $508 |
$547
9,379
kWh
|
- | - | - | - | |
| 11 | 3.1175: Use a different or recycled raw material | $481 | $481 | - | - | - | - |
$481
-
lb
|
|
| 12 | 3.5221: Recycle casting sand | $544 | $1,552 | - | - | - | - |
$544
-
lb
|
|
| 13 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $64 | $400 | - | - | - |
$64
-
gal
|
- | |
| TOTAL RECOMMENDED | $4,391 | $8,193 |
$1,676
30,188
kWh
|
$700 |
$926
-
MMBtu
|
$64
-
gal
|
$1,025
-
lb
|
||
| TOTAL IMPLEMENTED | $892 | $4,322 |
$348
6,448
kWh
|
- | - | - |
$544
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs