| Assessment Year | 1996 |
|---|---|
| Principal Product | Plastic Plumbing Fixtures |
| NAICS |
n/a
|
| SIC | 3088: Plastics Plumbing Fixtures |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
84,000
ft2
|
| Annual Production | 3,000,000
lb
|
| Production Hrs. Annual | 2,800
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $58,313 | 966,295 |
kWh
|
$0.060 |
| Electricity Demand | $10,504 | 4,040 |
kW-mo/yr
|
$2.60 |
| Electricity Fees | $4,412 | - |
|
- |
| Natural Gas | $40,012 | 9,266 |
MMBtu
|
$4.32 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,740 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,796 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $222 | $300 |
$222
3,810
kWh
|
- | - | - | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $1,166 | - |
$988
16,413
kWh
|
$178
-
kW-mo/yr
|
- | - | |
| 03 | 2.7135: Install occupancy sensors | $146 | $200 |
$124
2,052
kWh
|
$22
-
kW-mo/yr
|
- | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $1,041 | $3,720 |
$885
14,654
kWh
|
$156
-
kW-mo/yr
|
- | - | |
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $134 | $280 | - | - |
$134
-
MMBtu
|
- | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $75 | $234 | - | - |
$75
-
MMBtu
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $136 | $240 |
$115
2,052
kWh
|
$21
-
kW-mo/yr
|
- | - | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,533 | $500 |
$1,533
28,722
kWh
|
- | - | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,510 | $817 |
$1,255
23,447
kWh
|
$255
-
kW-mo/yr
|
- | - | |
| 10 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $3,777 | $188 | - | - | - |
$3,777
-
lb
|
|
| TOTAL RECOMMENDED | $9,740 | $6,479 |
$5,122
91,150
kWh
|
$632
-
kW-mo/yr
|
$209
-
MMBtu
|
$3,777
-
lb
|
||
| TOTAL IMPLEMENTED | $2,796 | $4,520 |
$2,640
47,186
kWh
|
$156
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs