Assessment Year | 2024 |
---|---|
Principal Product | metal filing cabinets for small-office/home-office (SOHO) |
NAICS | 337214: Office Furniture (except Wood) Manufacturing |
SIC | 2522: Office Furniture, Except Wood |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
260,000
ft2
|
Annual Production | 550,000
units
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $235,711 | 3,234,000 |
kWh
|
$0.073 | |
Electricity Demand | $105,309 | 8,859 |
kW-mo/yr
|
$11.89 | |
Electricity Fees | $7,159 | - |
|
- | |
Natural Gas | $294,537 | 45,512 |
MMBtu
|
$6.47 | |
Waste Disposal Costs | |||||
Water Usage | $9,400 | 2,540 |
Tgal
|
$3.70 | |
Water Disposal | $19,830 | 2,540 |
Tgal
|
$7.81 | |
TOTAL YEARLY COSTS | $671,946 | ||||
RECOMMENDED SAVINGS* | $142,818 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $41,655 | $181,095 |
$27,521
377,000
kWh
|
$7,134
-
kW-mo/yr
|
- | $7,000 | |
02 | 2.2511: Insulate bare equipment | $1,262 | $8,600 | - | - |
$1,262
-
MMBtu
|
- | |
03 | 2.2437: Recover waste heat from equipment | $8,062 | $21,900 | - | - |
$8,062
-
MMBtu
|
- | |
04 | 2.7313: Recycle air for heating, ventilation and air conditioning | $65,735 | $420,000 | - | - |
$65,735
-
MMBtu
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,359 | $16,560 |
$9,992
136,880
kWh
|
$3,367
-
kW-mo/yr
|
- | - | |
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $12,745 | $18,000 |
$12,745
174,590
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $142,818 | $666,155 |
$50,258
688,470
kWh
|
$10,501
-
kW-mo/yr
|
$75,059
-
MMBtu
|
$7,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs