Assessment Year | 2009 |
---|---|
Principal Product | Sheet Metal Fabrication and Machined Parts |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | less than $500 k |
# of Employees | 35 |
Plant Area |
80,000
ft2
|
Annual Production | 3,750
pieces
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $103,166 | 983,640 |
kWh
|
$0.10 |
Natural Gas | $70,531 | 6,330 |
MMBtu
|
$11.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,575 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,877 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $13,072 | $16,185 |
$1,391
14,195
kWh
|
- |
$11,681
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,384 | $29,087 |
$6,726
64,916
kWh
|
$1,658
-
kW-mo/yr
|
- | |
03 | 2.7224: Reduce space conditioning during non-working hours | $7,645 | - |
$3,900
39,800
kWh
|
- |
$3,745
-
MMBtu
|
|
04 | 2.1123: Install automatic stack damper | $3,637 | $1,000 | - | - |
$3,637
-
MMBtu
|
|
05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,711 | $6,468 |
$1,711
17,463
kWh
|
- | - | |
06 | 2.2437: Recover waste heat from equipment | $1,230 | $1,500 | - | - |
$1,230
-
MMBtu
|
|
07 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,084 | $2,812 | - | - |
$1,084
-
MMBtu
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $797 | $1,907 |
$621
6,338
kWh
|
$176
-
kW-mo/yr
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $487 | $2,374 |
$372
3,794
kWh
|
$115
-
kW-mo/yr
|
- | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,334 | $1,000 |
$1,058
10,800
kWh
|
$276
-
kW-mo/yr
|
- | |
11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $194 | - |
$154
1,575
kWh
|
$40
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $39,575 | $62,333 |
$15,933
158,881
kWh
|
$2,265
-
kW-mo/yr
|
$21,377
-
MMBtu
|
||
TOTAL IMPLEMENTED | $19,877 | $35,868 |
$12,677
125,648
kWh
|
$2,225
-
kW-mo/yr
|
$4,975
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs