Assessment Year | 1996 |
---|---|
Principal Product | thermoplastics |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $50 M to 100M |
# of Employees | 210 |
Plant Area |
198,000
ft2
|
Annual Production | 20,000,000
lb
|
Production Hrs. Annual | 6,528
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,000,989 | 21,123,095 |
kWh
|
$0.047 |
Electricity Demand | $412,105 | 45,728 |
kW-mo/yr
|
$9.01 |
Natural Gas | $199,467 | 58,434 |
MMBtu
|
$3.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $51,595 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $8,670 | $77,600 | n/a |
$6,700
108,441
kWh
|
$1,970
-
kW-mo/yr
|
- | - |
02 | 2.3212: Optimize plant power factor | $29,294 | $54,000 | n/a | - | - | $29,294 | - |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,285 | $240 | n/a |
$4,285
75,029
kWh
|
- | - | - |
04 | 2.4221: Install compressor air intakes in coolest locations | $3,685 | $1,000 | n/a |
$3,685
59,789
kWh
|
- | - | - |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $413 | $1,800 | n/a |
$292
6,741
kWh
|
$121
-
kW-mo/yr
|
- | - |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $654 | $1,030 | n/a |
$363
10,551
kWh
|
$291
-
kW-mo/yr
|
- | - |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,329 | $3,000 | n/a | - | - | - |
$3,329
-
MMBtu
|
08 | 2.6218: Turn off equipment when not in use | $1,197 | - | n/a |
$1,197
19,930
kWh
|
- | - | - |
09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $68 | $100 | n/a | - | - | - |
$68
-
MMBtu
|
TOTAL RECOMMENDED | $51,595 | $138,770 |
$16,522
280,481
kWh
|
$2,382
-
kW-mo/yr
|
$29,294 |
$3,397
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs