| Assessment Year | 1994 |
|---|---|
| Principal Product | machined parts |
| NAICS |
n/a
|
| SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
| Sales Range | $5 M to 10M |
| # of Employees | 100 |
| Plant Area |
49,000
ft2
|
| Annual Production | 4,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $60,058 | 1,032,532 |
kWh
|
$0.058 |
| Natural Gas | $4,078 | 762 |
MMBtu
|
$5.35 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $27,764 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,667 | $500 | n/a |
$8,667
148,886
kWh
|
- | - |
| 02 | 2.4133: Use most efficient type of electric motors | $7,724 | $11,100 | n/a |
$7,724
132,767
kWh
|
- | - |
| 03 | 2.8114: Change rate schedules or other changes in utility service | $3,504 | - | n/a | - | - | $3,504 |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,685 | $1,147 | n/a |
$2,685
46,307
kWh
|
- | - |
| 05 | 2.3212: Optimize plant power factor | $2,352 | $7,000 | n/a |
$2,352
-
kWh
|
- | - |
| 06 | 2.2531: Re-size charging openings or add movable cover or door | $1,035 | $500 | n/a |
$274
4,689
kWh
|
$761
-
MMBtu
|
- |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $733 | $900 | n/a |
$733
12,603
kWh
|
- | - |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $553 | $117 | n/a |
$553
9,672
kWh
|
- | - |
| 09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $252 | $380 | n/a | - |
$252
-
MMBtu
|
- |
| 10 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $181 | $600 | n/a |
$181
879
kWh
|
- | - |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $78 | $200 | n/a |
$78
1,465
kWh
|
- | - |
| TOTAL RECOMMENDED | $27,764 | $22,444 |
$23,247
357,268
kWh
|
$1,013
-
MMBtu
|
$3,504 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs