| Assessment Year | 2007 |
|---|---|
| Principal Product | Profile and Sheet Extrusions |
| NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 48 |
| Plant Area |
36,000
ft2
|
| Annual Production | 3,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $174,928 | 2,525,760 |
kWh
|
$0.069 |
| Electricity Demand | $54,613 | 6,446 |
kW-mo/yr
|
$8.47 |
| Electricity Fees | $4,274 | - |
|
- |
| Natural Gas | $8,418 | 585 |
MMBtu
|
$14.39 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,064 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,453 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6231: Utilize controls to operate equipment only when needed | $3,945 | $711 |
$3,945
55,230
kWh
|
- | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,951 | $2,939 |
$7,289
102,039
kWh
|
$1,662
-
kW-mo/yr
|
|
| 03 | 2.4239: Eliminate or reduce compressed air usage | $9,919 | $5,140 |
$8,077
113,071
kWh
|
$1,842
-
kW-mo/yr
|
|
| 04 | 2.6231: Utilize controls to operate equipment only when needed | $1,019 | $711 |
$1,019
14,270
kWh
|
- | |
| 05 | 2.6231: Utilize controls to operate equipment only when needed | $4,266 | $4,307 |
$3,432
48,043
kWh
|
$834
-
kW-mo/yr
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,999 | $3,759 |
$2,426
33,958
kWh
|
$573
-
kW-mo/yr
|
|
| 07 | 2.7135: Install occupancy sensors | $511 | $1,404 |
$437
6,118
kWh
|
$74
-
kW-mo/yr
|
|
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,115 | $6,510 |
$1,722
24,111
kWh
|
$393
-
kW-mo/yr
|
|
| 09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,339 | $4,380 |
$1,090
15,260
kWh
|
$249
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $35,064 | $29,861 |
$29,437
412,100
kWh
|
$5,627
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $6,453 | $14,649 |
$5,238
73,329
kWh
|
$1,215
-
kW-mo/yr
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs