Assessment Year | 1994 |
---|---|
Principal Product | Electronics/Pneumatics; Aluminum Stampings & Castings |
NAICS |
n/a
|
SIC | 3363: Aluminum Die-Castings |
Sales Range | $1 M to 5M |
# of Employees | 92 |
Plant Area |
42,400
ft2
|
Annual Production | 12,000
pieces
|
Production Hrs. Annual | 3,432
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $157,351 | 1,706,624 |
kWh
|
$0.092 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,272 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,959 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $3,906 | $1,523 |
$3,906
40,739
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,740 | $750 |
$1,740
17,878
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,053 | $1,556 |
$1,053
11,723
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $950 | $420 |
$950
10,258
kWh
|
- | - | |
05 | 3.1244: Reduce solution drag-out to prevent solution loss | $870 | $800 | - | - | $870 | |
06 | 2.7135: Install occupancy sensors | $598 | $90 |
$598
5,862
kWh
|
- | - | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $155 | $100 | - |
$155
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $9,272 | $5,239 |
$8,247
86,460
kWh
|
$155
-
MMBtu
|
$870 | ||
TOTAL IMPLEMENTED | $4,959 | $3,079 |
$4,959
52,462
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs